ANGLE BRACKET FOR SHEAR LOADS
TITAN F
TITAN F is the angle plate for shear loads in Timber frame constructions. Made of bright zinc plated carbon steel, it is ideal for shear joints between floor and wall and between wall and wall.
TITAN F PLATE FOR TIMBER, HIGH SHEAR STRENGTH IN ALL SITUATIONS
The TITAN F angle bracket for timber is designed for fastening on platform beams or on the stringers of the frame structures. It is designed to offer two fixing possibilities, in order to avoid interference with the rebars in the concrete support.
Thanks to the lowered position of the holes on the vertical flange, it offers excellent shear strength values even on low height platform beams. R2,k up to 42,5 kN on both timber and concrete. In combination with XYLOFON PLATE it effectively limits acoustic bridges and reduces walking vibrations of timber floors, ensuring an excellent cost-performance ratio.
Thanks to the high shear strength it is possible to optimize the number of fastenings. TITAN F angle brackets for timber are designed for timber-to-concrete and timber-to-timber shear joints for timber panels and beams on CLT, LVL, solid timber, glulam, framed structures and timber-based panels.
Documents
Technical data sheets
|
|
---|---|
ETA Certificate
|
|
Declaration of performance (DOP) | Download |
Item specification
|
|
File CAD
|
|
File BIM.ifc
|
|
File BIM.rfa
|
TITAN F - TCF
CODE | B
[mm]
|
P
[mm]
|
H
[mm]
|
s
[mm]
|
pcs. |
---|---|---|---|---|---|
TCF200 | 200 | 103 | 71 | 3 | 10 |
TITAN F - TTF
CODE | B
[mm]
|
P
[mm]
|
H
[mm]
|
s
[mm]
|
pcs. |
---|---|---|---|---|---|
TTF200 | 200 | 71 | 71 | 3 | 10 |
Specifications
Supply and installation of angle bracket for shear forces for timber structures, Type TITAN F.
CE marking in accordance with ETA 11/0496
Field of use:
- Joints for timber-to-timber, timber-to-concrete and timber-to-steel
Material:
- Z275 Bright zinc plated carbon steel, three dimensional perforated plate
Geometry:
- B (mm) = :
- P (mm) = :
- H (mm) = :
-Thickness s (mm) = :
Indications for installation and mechanical performance as reported in the product data sheets and provided by the technical drawings of the project.